10 shdsl port management, 1 overview of shdsl port management, Shdsl port management – Westermo RedFox Series User Manual

Page 204: Chapter 10

Advertising
background image

Westermo OS Management Guide

Version 4.17.0-0

Chapter 10

SHDSL Port Management

Wolverine family switches (DDW225/DDW-226/DDW-142/DDW-142-485) are equipped
with two SHDSL ports (Symmetric High-speed Digital Subscriber Line), enabling
LAN networks to be extended over legacy copper cabling.

10.1

Overview of SHDSL Port Management

10.1.1

SHDSL overview

With SHDSL Ethernet LANs can be extended over legacy copper cabling. Switches
can be connected in a simple point-to-point setup, but also in multi-drop and ring
topologies, as shown in

fig. 10.1

.

In a SHDSL connection, the port on one unit shall be configured as Central Of-
fice
(CO) and the port on the other unit as Customer Premises Equipment (CPE).
SHDSL ports are named according to the name convention described in

sec-

tion 8.1.1

). By default 1/1 or DSL 1 is configured as CPE while the 1/2 (or DSL 2)

is configured as CO.

SHDSL support in WeOS is based on Ethernet First Mile (EFM) technology, and
SHDSL can to a large extent be treated in the same way as Ethernet ports, e.g.,
you can add SHDSL ports to VLANs (

chapter 13

), you can run link-layer redun-

dancy protocols such as FRNT (

chapter 14

) and RSTP (

chapter 16

) over them,

etc. Settings specific to SHDSL ports are described in

section 10.1.2

while port

settings of more general nature is covered in

section 10.1.3

.

204

➞ 2015 Westermo Teleindustri AB