The WeOS SNMP trap support is integrated with the WeOS alarm handling sys-
tem (see

section 24.1

). This means that you as an operator have fine-grained

control of which traps to send. All traps in the list below, except Coldstart and
lldpRemTablesChange, can be controlled via the alarm handling system.

Link Alarm: A trap is generated on link up or link down, given that Link Alarm

is enabled on that specific port (see

sections 24.1.3

and

8.1.5

).

Link Down OID: iso(1).org(3).dod(6).internet(1).snmpV2(6).snmpModules(3).
snmpMIB(1).snmpMIBObjects(1).snmpTraps(5).linkDown(3)

Link Up OID: iso(1).org(3).dod(6).internet(1).snmpV2(6).snmpModules(3).
snmpMIB(1).snmpMIBObjects(1).snmpTraps(5).linkUp(4)

Note

When a port is being reconfigured, link down and link up events are
likely to occur. If link-alarm is enabled on that port, a couple of SNMP
traps are likely to be generated as a side-effect of the port reconfigura-
tion.

Cold Start: A trap is generated when a system comes up.

OID: iso(1).org(3).dod(6).internet(1).snmpV2(6).snmpModules(3).
snmpMIB(1).snmpMIBObjects(1).snmpTraps(5).coldStart(1)

LLDP Remote System Update: A trap is generated when a remote system

has updated.

OID: iso(1).std(0).iso8802(8802).ieee802dot1(1).ieee802dot1mibs(1).
lldpMIB(2).lldpNotifications(0).lldpNotificationPrefix(0).lldpRemTablesChange(1)

Digital-In: A trap is generated when the voltage level on the pins of a

digital-in sensor changes from high to low, or low to high.

Digital-In High OID: iso(1).org(3).dod(6).internet(1).private(4).
enterprises(1).westermo(16177).common(2).weos(1).notifications(6).

sensorNotifications(1).sensorNotificationPrefix(0).digitalInHigh(1)

Digital-In Low OID: iso(1).org(3).dod(6).internet(1).private(4).
enterprises(1).westermo(16177).common(2).weos(1).notifications(6).

sensorNotifications(1).sensorNotificationPrefix(0).digitalInLow(2)

Power Supply: A trap is generated when the voltage level on any of the

power feeds changes from high to low, or low to high.

64