Westermo OS Management Guide

Version 4.17.0-0

Use ”path-cost auto” to have the uplink’s path-cost depend on its link
speed and duplex mode. Use ”path-cost COST” to set a static path-cost
for the uplink. ”no path-cost” will reset the path cost to the default setting
(auto).

”show path-cost” will show the configured uplink path-cost.

Default values Auto

15.3.12

Set Multi-Link Dual-Homing Uplink Priority

Syntax [no] priority <1..65535> [adjust <DELTA>]

Context

Dual-Homing Uplink Configuration

context

Usage Configure uplink priority, and optionally enable sticky uplink election by

setting adjust value.

❼ Use ”priority VALUE” to set priority value. A lower value increases

the chance for this uplink to be elected as active uplink (lower is better).
With equal path-cost (

section 15.3.11

), an uplink with ”priority 100”

is preferred as uplink over an uplink with ”priority 110”.

❼ Use the optional ”adjust DELTA” setting to improve its priority (i.e.,

lower its priority with the specified ”DELTA”) once the uplink is elected
as active uplink. This gives a sticky uplink behaviour where shifting
active uplink will be less common.

Consider the following example with uplink A (”priority 100”), uplink
B
(”priority 110 adjust 20”), and uplink C (”priority 120 adjust
40”
), and where uplink A came up first and is the active uplink. If uplink
A
goes down, uplink B takes over as it has lower priority than uplink
C
(110 < 120). Uplink B will then apply its adjustment and announce
priority to 90 (110 20) in its hello messages. Uplink B will stay as
active uplink even if uplink A comes up again (90 < 100).

”show priority” will show the configured uplink priority.

Default values priority 128 (no adjustment)

15.3.13

Show FRNT Ring Coupling Status

Syntax show coupling