Version 4.17.0-0

Use ”show focal-point” to show whether the unit is configured as focal-
point or member switch

Default values focal-point

14.4.3

FRNT Ring Ports

Syntax ring-ports <PORT-M,PORT-N>

Context

FRNT Configuration

context

Usage Set the physical ports (Ethernet ports or SHDSL ports) to use as FRNT

ports ”M” and ”N”.

For each FRNT instance, there are two FRNT ports named Port ”M” and Port
”N”. On a member switch Port ”M” and ”N” have similar roles, however, on a
focal point their roles differ - when the ring is fully connected the focal point
will put its Port ”M” in BLOCKING state.

Note

For restrictions on how to select FRNT ports, see

section 14.1.2

.

Use ”show ring-ports” to show configured FRNT ring ports.

Default values Not applicable

14.4.4

Show FRNT ring status

Syntax show rings

Context

Admin Exec

context.

Usage Show status of configured FRNT rings. This will provide information

❼ whether the ring is up (ring mode) or if the ring is broken (bus mode).

Note: A focal point switch will detect ring failures located anywhere in
the ring, while a member switch can only detect local failures (local
FRNT port is down, or if a neighbour is down).

❼ If the FRNT ports on this switch are connected in-line with the M/N ports

of the focal-point, or if they are logically swapped (i.e., if the FRNT ports’