25 logging support, Chapter 25, Logging support – Westermo RedFox Series User Manual

Page 582

Advertising
background image

Westermo OS Management Guide

Version 4.17.0-0

Chapter 25

Logging Support

This chapter describes WeOS support for alarm and generic event logging.

In WeOS general events detected by the system (such as user login attempts), as
well as alarm events defined by configured alarm triggers (see

chapter 24

) can

be logged for further analysis. Three logging methods are available:

Logging to file: General events and alarm events are always logged to a

local log file.

Logging to console: It is possible to direct logging messages to the console

port. Messages of severity level DEBUG or higher are shown on the console
port.

Logging to a remote syslog server: Logging messages can be sent to a

remote syslog server for further processing. Messages of severity level NO-
TICE
or higher are forwarded to the remote syslog server(s).

As of WeOS v4.17.0 logging support is only available via the CLI. The severity
thresholds for console and remote syslog logging are not configurable, however,
such support is planned.

582

➞ 2015 Westermo Teleindustri AB

Advertising