Westermo OS Management Guide

Version 4.17.0-0

❼ Severity: By default, active severity is WARNING and inactive severity

is NOTIFY.

❼ Action: By default, the trigger is mapped to the default action profile

(action 1).

In this example two temperature triggers are created, one to give alarm if
the temperature drops below 10

C, and a second trigger to create an alarm

if the temperature rises above 60

C.

Example

example:/config/alarm/#> trigger temperature
example:/config/alarm/trigger-2/#> sensor 1
example:/config/alarm/trigger-2/#> threshold falling -10 rising -5
example:/config/alarm/trigger-2/#> condition low
example:/config/alarm/trigger-2/#> end
example:/config/alarm/#> trigger temperature
example:/config/alarm/trigger-3/#> sensor 1
example:/config/alarm/trigger-3/#> threshold falling 55 rising 60
example:/config/alarm/trigger-3/#> condition high
example:/config/alarm/trigger-3/#> end
example:/config/alarm/#> show
Trigger

Type

Enabled

Action

Source

===============================================================================

1

frnt

YES

1

1

2

temperature YES

1

1

3

temperature YES

1

1

Action

Targets

===============================================================================

1

snmp log led digout

===============================================================================
Summary alarm traps: Disabled

example:/config/alarm/#>

24.3.2.6

FRNT Trigger Configuration Example

An FRNT trigger exists in the factory default configuration.

Thus, when FRNT

is enabled, FRNT alarms will be presented on the default alarm targets without

requiring the user to create a trigger.

Syntax trigger frnt

Context

Alarm Configuration

context

Usage Create an FRNT trigger, and enter the

Alarm Trigger Configuration

context

for this trigger.

560