Westermo OS Management Guide

Version 4.17.0-0

❼ Enable/Disable: By default, the trigger is enabled.
❼ Condition: By default, the alarm condition is set to high. That is, usage

levels below the falling threshold are considered normal, and tempera-
tures above the rising threshold is considered an alarm situation.

❼ Severity: By default, active severity is WARNING and inactive severity

is NOTIFY.

❼ Action: By default, the trigger is mapped to the default action profile

(action 1).

In this example a PoE trigger is created to give an alarm if the usage rises
above 80%.

Example

viper:/config/alarm/#> trigger poe
viper:/config/alarm/trigger-2/#> threshold rising 80 falling 75
viper:/config/alarm/trigger-2/#> condition high
viper:/config/alarm/trigger-2/#> end
viper:/config/alarm/#> show
Trigger

Type

Enabled

Action

Source

===============================================================================

1

frnt

YES

1

Instance 1

2

poe

YES

1

1

Action

Targets

===============================================================================

1

snmp log led

===============================================================================
Summary alarm traps: Disabled

viper:/config/alarm/#>

24.3.2.11

Microlok Trigger Configuration Example

Syntax trigger microlok

Context

Alarm Configuration

context

Usage Create a Microlok session summary alarm trigger, and enter the

Alarm

Trigger Configuration

context for this trigger.

Additional settings for link-alarm triggers are listed below.

As of WeOS

v4.17.0 there can only be one Microlok Gateway instance, thus the gate-
way instance (i.e., instance 1) is implicit.

566