Westermo RedFox Series User Manual

Page 211

Advertising
background image

Westermo OS Management Guide

Version 4.17.0-0

Continued from previous page

DSL Rate

Speed setting is only valid if the port is configured as CO (the
CPE rate setting is not used, since the CPE speed automati-
cally follows the CO to which it becomes connected).
See

section 10.1.2

for information on using SHDSL-turbo

speed data rates.
Default is Auto.

Mode

The noise-margin mode. The noise-margin mode setting is
only valid if the port is configured as CO (the CPE setting is not
used, since the CPE noise-margin mode automatically follows
the CO to which it becomes connected).
The CO can be configured to choose a faster less reliable
speed (High Speed), a slower more reliable speed (Reliable),
or a tradeoff between these two objectives (Normal).
Default is Normal.

Link Alarm

When link alarm is enabled an alarm will be generated if port
link is down. Alarms trigger an SNMP trap message to be sent
and alarms to be shown on the administration web.

Edit

Click this icon to edit a port’s settings.

➞ 2015 Westermo Teleindustri AB

211