Version 4.17.0-0

Inbound rate limit: Setting the inbound rate limit is possible on DSL ports,

but is likely of less interest than on Ethernet ports, since the DSL data rates
are primarily limited by the rate of the DSL line. See also

sections 8.1.6

and

11.1.1

.

Outbound traffic shaping: Setting the outbound rate limit (traffic shaping)

is possible on DSL ports, but is likely of less interest than on Ethernet ports,
since the DSL data rates are primarily limited by the rate of the DSL line.
Furthermore, outbound traffic shaping in frames per second mode is not
available on DSL ports. See also

sections 8.1.7

and

11.1.1

.

Fall-back default-VID: The fall-back default VID setting is only of interest

for the special case when untagged packets are received over a link only
associated with tagged VLANs.

Ethernet settings for port speed/duplex mode, and MDI/MDIX mode do not apply
to xDSL ports, thus are not configurable.

Note

As of WeOS v4.17.0, enabling/disabling flow control (as described in section

section 8.1.3

) has no effect on xDSL ports.

11.1.4

Connecting to your ISP over an xDSL line

Recommendation: Use Basic Setup in Web

The simplest way to configure your Falcon unit to connect to your ISP is to
use the Basic Setup web page, see

section 11.2.1

.

This section is intended (1) for those who wish to configure the Falcon via
the CLI, and (2) for those looking for more background details on how to
configure Falcon as an xDSL router or bridge.

This section describes the most common steps to configure your Falcon xDSL
router to connect to your ISP. Although many configuration settings are affected,
setting up your ISP should be straight-forward:

❼ The factory default configuration of xDSL are adapted to using the Falcon as

an xDSL router.

❼ On the Falcon xDSL router, the web interface includes a basic setup page,

for easy configuration of the most common use cases, see

section 11.2.1

.