Default value RS-232 for ”combo” RS-232/422/485 ports and RS-485 for ”combo”
RS-422/485 ports.
38.3.9
Configure serial port termination
Syntax [no] terminate [rx] [tx]
Context
context (RS-422 and RS-485 modes only)
Usage Configure serial port termination setting. The termination setting is only
applicable for ports operating in RS-422 or RS-485 mode.
❼ RS-422 (4-wire): Use ”terminate rx” to enable termination on the re-
ceive pair, ”terminate tx” to enable termination on the transmit pair,
and ”terminate rx,tx” to enable termination on both the receive and
transmit pairs. ”no terminate” will disable termination.
❼ RS-485 (2-wire): Use ”terminate” to enable termination and ”no terminate”
to disable termination.
Use ”show ” to shether termination is enabled or disabled. In RS-422 mode,
the port pairs, for which termination is enabled, are listed (RX, TX, or both
RX and TX).
Default value Disabled (no terminate)
38.3.10
Enabling/disabling a serial (RS-232/422/485 ”combo”) port
Syntax [no] enable
Context
context
Usage Enable/disable a serial port. (Only applicable to ”combo” RS-232/422/485
serial ports. Regular RS-232 ports and ”combo” RS-422/485 serial ports are
always enabled.)
Use ”show enable” to show whether the ”combo” RS-232/422/485 serial
port is enabled or disabled.
Default value Disabled (no enable)