Version 4.17.0-0

Default values (empty)

20.2.5

Set System Time Zone

Syntax [no] timezone <TIMEZONE>

Context

General System Configuration

context.

Usage Set system time zone string.

Note

For information of available time zone settings, see

section 20.2.8

.

”no timezone” resets the timezone to its default value (Etc/UTC).

Use ”show timezone” to view the configured timezone setting.

Default values Etc/UTC

20.2.6

CPU bandwidth limitation

Syntax [no] cpu-bandwidth-limit <auto|<64-1000000>|<7700-1488000> fps>

Context

General System Configuration

context

Usage Limit the traffic sent to the CPU in kbit/s or frames per second (traffic

from the CPU is not affected). It is also possible use ISO modifiers k/M/G,
e.g., 256k or 10M as specifiers for kbps and Mbps.

Note

CPU bandwidth limit in frames per second mode is available on all
WeOS products, with exceptions for some RedFox models. On Red-
Fox, the frames per second mode is available for products based on
the ”Corazon” platform, including RedFox Industrial Rack, newer Red-
Fox Rail (RFR-212-FB)[

50

] and newer RedFox Industrial[

48

]. But the

frames per second mode is not available on RedFox products based on
the (older) ”Atlas” platform, i.e, RedFox Industrial listed in [

47

] or older

RedFox Rail (RFR-12-FB).

Set values are rounded off to the nearest possible HW setting.