background image

4. Control panel (only type SFC−LACI−...−H2)

4−16

Festo GDCP−SFC−LACI−DN−EN en 0812NH

4.5.4

[Settings] [Position set]

Parameterising the position set table

·

Observe the instructions in section 5.2.8.

·

Select first the number of the desired positioning record.
The following settings refer to the currently selected
positioning record.

[Position set]

Param.

Description

[Position nr]

Nr

Number of the position record [1 ... 31]

[Pos set mode]

[absolute/
relative]

Positioning mode
absolute = position specification refers to the project zero point
relative

= position specification refers to the current position

e

= energy−optimized path generator

[Position]

*)

xt

Target position in [mm]

[Velocity]

v

Positioning speed in [mm/s]

[Acceleration]

a

Acceleration in [mm/s

2

]

[Deceleration]

d

Deceleration in [mm/s

2

]

[Jerk Acc]

ja

Acceleration jerk in [m/s

3

]

[Jerk Dec]

jd

Deceleration jerk in [m/s

3

]

[Work load]

m

Applied load (= workpiece mass) in [g]

Time MC

t_MC

Damping time (time between reaching the target window and
setting Motion Complete")

[SAVE...]

Saves parameters to the EEPROM

*)

Teaching is only possible after a successful homing run.