B. Parametrizing via field bus
B−48
Festo GDCP−SFC−LACI−DN−EN en 0812NH
B.4.5
Diagnosis
Description of the method of operation of the diagnostic
memory: see section 6.4.2.
Diagnostic Event
PNU
200
1 ... 16
d
uint8
r
Description
Type of fault or diagnostic information saved in the diagnostic memory.
Displays whether an incoming or outgoing fault is saved.
Value
Type of diagnostic event
0 (0x00):
No fault (or diagnostic message deleted)
1 (0x01):
Incoming fault
2 (0x02):
Outgoing fault
3 (0x03):
(reserved)
4 (0x04):
Overrun time stamp
Event 1 200
1
Active diagnostic event
Event 2 200
2
Previous diagnostic event
Event ... 200
...
...
Event 16 200
16
Oldest saved diagnostic event
CI
20C8h
01 ... 10h
uint8
r
DeviceNet
C: 101
Aā: 1
I: 1 ... 16
uint8
r