Festo Контроллеры двигателя SFC-LAC User Manual
Page 288
![background image](/manuals/464472/288/background.png)
B. Parametrizing via field bus
B−68
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Record Control Byte 2
PNU
402
1 ... 32
d
Array
uint8
rw
Description
Record control byte 2
For record selection: Switching condition for chained records
(see section 5.6.5)
Values:
Bit 0:
= 0 No record chaining
= 1 Record chaining
Bit7:
= 0 Record chaining is not locked out
= 1 Record chaining is locked out
Record 0
(positioning record 0)
402
1
(positioning record 0)
Do not use (Homing)
Record 1
(positioning record 1)
402
2
(positioning record 1)
Record control byte 2 Positioning record 1
Record ...
(positioning record
)
402
...
(positioning record ...)
Record control byte 2 Positioning record 2 ... 30
Record 31
(positioning record 31)
402
32
(positioning record 31)
Record control byte 2 Positioning record 31
CI
20EBh
01h ... 20h
uint8
rw
DeviceNet
C: 104
Aā: 2
I: 1 ... 32
uint8
rw