5. Commissioning

5−71

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Overview of parameters involved (see section B.4.8)

Description

FCT

PNU

CI

Positioning mode

Basic velocity

x

540

21F8h

Acceleration

x

541

20EE/22h

Deceleration

x

542

20EF/22h

Acceleration jerk

x

543

20E7/22h

Applied load

x

544

20E8/22h

Deceleration jerk

x

547

21E1/22h

Damping time

x

1023

20E6/22h

Force control

1)

Stroke limitation

x

510

60F6/01h

Minimum force (fix 30 % of the rated value)

x

511

60F6/05h

Maximum force

x

512

6072h

Force target window (tolerance)

x

552

60F6/03h

Force damping time in [ms]

x

553

60F6/04h

Max. permitted speed

x

554

60F6/02h

Start (FHPP)

CPOS.B1 START = positive edge

Feedback (FHPP)

SPOS.B2 = 0: Motion complete
SPOS.B1 = positive edge: Acknowledge start
SPOS.B4 = 1: Drive moving

Prerequisites

Device control by PLC/field bus
Controller must be in status Operation enabled"

1)

Further parameters:
6071h Target torque

6076h

Rated torque

6077h Actual torque

6087h

Torque slope

6088h Torque profile type

CDIR.B5 Stroke limitation active/inactive

Tab. 5/18:

Parameters involved in Direct mode