5 teach the axis zero point, Teach the axis zero point – Festo Контроллеры двигателя SFC-LAC User Manual

Page 120

Advertising
background image

5. Commissioning

5−16

Festo GDCP−SFC−LACI−DN−EN en 0812NH

5.2.5

Teach the axis zero point

Factory setting

Axis zero point with:
ć Homing to reference switch:

0 mm

ć Homing to negative fixed stop:

+1 mm

ć Homing to a positive fixed stop:

ć1 mm

Note
Risk of overloading when homing to stop:
The drive must not press continuously against a
mechanical stop (excessive warming).

·

Make sure that the axis zero point is at least 1 mm away
from the mechanical stop.

This causes the drive to leave the mechanical stop after
recognising the reference point.

If necessary, teach the

axis zero point:

Warning
The drive will move during teaching.

·

Make sure that nobody can reach into the positioning
range of the moveable load and that there are no objects
in its path.

1. Select [Settings] [Axis parameter] [Zero point].

2. Move the drive manually to the desired axis zero point

using the arrow keys.

3. Accept the position reached with OK <Enter>.

4. Save the parameter settings in EEPROM with the

[SAVE]

menu command.

5. Perform another homing run (see section 5.2.4).

When homing is concluded, the drive stands at the new
axis zero point.

} Settings

Axis parameter

Zero point
SW–limit–neg
SW–limit–pos
SAVE

Advertising