5. Commissioning
5−10
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Station number (MAC ID)
ć
Permitted station numbers: 0 ... 63
ć
An invalid station number is preset (shown on control
panel as ???").
This is to make sure that a correct address is set during
commissioning or exchange.
Baudrate (baud rate)
ć
Possible baud rates: 125, 250, 500 kBd
ć
An invalid baud rate is preset (shown on control panel as
???").
This is to make sure that a correct baud is set during
commissioning or exchange.
I/O Datalength (data length)
ć
The following settings are possible:
ć
8 bytes:
FHPP standard (control of the SFC−LACI takes place
according to Festo Handling and Positioning Profile)
ć
16 bytes:
FHPP standard and FHPP−FPC (additional use of the
FPC for parameterising the SFC−LACI). It is transmitted
in 3 telegrams.
ć
An invalid data length is preset (displayed as ???" on the
control panel). This is to make sure that the correct data
length is set during commissioning or exchange.
} Settings
BUS parameter
MAC ID
DeviceNet MAC ID
06 dec, 06 hex
ESC <Menu>
<––>
OK <Enter>
} Settings
BUS
parameter
Baudrate
BUS Baudrate
125 kBd
ESC <Menu>
<––>
OK <Enter>
} Settings
BUS parameter
I/O Datalength
I/O Datalength
08 byte
ESC <Menu>
<––>
OK <Enter>