5. Commissioning

5−33

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Assignment of the control bytes (overview)

CCON

B7
OPM2

B6
OPM1

B5
LOCK

B4
ć

B3 (F)
RESET

B2
BRAKE

B1
STOP

B0
ENABLE

Operating mode
selection

HMI
access
blocked

ć

Acknowl.
error

Clamping
unit

Stop

Enable
drive

CPOS

B7
ć

B6
CLEAR

B5
TEACH

B4
JOGN

B3
JOGP

B2 (F)
HOM

B1 (F)
START

B0
HALT

ć

Clear reĆ
maining
path

Teach
value

Jog
negativ

Jog
positiv

Start
homing

Start
position.
task

Halt

CDIR

(only

B7
FUNC

B6
FAST

B5
XLIM

B4
CONTT

B3
CONT

B2
COM2

B1
COM1

B0
ABS

(only
direct
mode)

ć

ć

Deactiv.
stroke
limit

Contin.
mode
toggle

ConĆ
tinuous
mode

Control mode
(Position, force ...)

AbsoĆ
lute/
relative

ć : reserved; (F): edge−sensitive

Assignment of the status bytes (overview)

SCON

B7
OPM2

B6
OPM1

B5
HMI

B4
24VL

B3
FAULT

B2
WARN

B1
OPEN

B0
ENABLED

Acknowledgement of
operating mode

Control
hierarchy

Load
voltage
applied

Error

Warning

OperĆ
ation
enabled

Drive
enabled

SPOS

B7
REF

B6
STILL

B5
DEV

B4
MOV

B3
TEACH

B2
MC

B1
ACK

B0
HALT

Drive refĆ
erenced

DownĆ
time
monitor

Contour
error

Axis is
moving

Acknowl.
teach or
sample

Motion
complete

AcknowlĆ
edge
start

Halt

SDIR

(only

B7
FUNC

B6
FAST

B5
XLIM

B4
VLIM

B3
CONT

B2
COM2

B1
COM1

B0
ABS

(only
direct
mode)

ć

ć

Stroke
limit
reached

Velocity
limit
reached

ć

Reply message conĆ
trol mode (position,
force, ...)

AbsoĆ
lute/
relative

ć : reserved