A. Technical appendix

A−4

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Electrical data

Load voltage supply
Ĉ Nominal voltage
Ĉ Nominal current (max. continuous

motor current)

Ĉ Peak current

Power connection, pins A1, A2)
48 VDC (+5/−10 %) (Load power down:

Ţ 36 V)

10 A

20 A

Logic voltage supply
Ĉ Nominal voltage
Ĉ Nominal current

Power connection, pins 1, 2
24 VDC ±10 %
3.8 A (when using the local digital outputs, see section 3.2)

Protection against electric shock
(protection against direct and indirect
contact as per IEC/DIN EN 60204−1)

By means of PELV power circuit
(Protected Extra−Low Voltage)

Parameterising interface specification

RS232, 38400 Baud, see chapter 3.5

DeviceNet data

Version
Ĉ Physical layer
Ĉ Data link layer

As per ISO 11898 (corresponds to DS102)
As per CAN specification 2.0

DeviceNet specification

As per IEC 62026 and EN 50325
Predefined connection set: Group 2 slave only"

Manufacturer ID

Festo Corporation" 26 (0x1A)

DeviceNet device type

Communication adapter" (0x0C / 12)

Product code

9011

Address range (MAC ID)

0 ... 63

Baud rate

125, 250, 500 kBaud

Interface
Ĉ Plug connector
Ĉ Electrical isolation
Ĉ Integrated bus terminal

Sub−D 9−pin, plug
Yes
No

Cable type

Depends on length of cable and field bus baud rate,
seeĂcontroller manual