B. Parametrizing via field bus
B−4
Festo GDCP−SFC−LACI−DN−EN en 0812NH
B.1.2
Parameter overview (class, attribute, instance)
Explicit Messaging
The following tables contain all defined parameters with
indication of the Class (CLS), Attribute (ATTR) and Instance
(INST) for access via Explicit Messaging".
FPC
For access via FPC (within the cyclic I/O data), the FHPP
parameter number (PNU with subindex) is used.
A detailed description of the parameters can be found under
the specified FHPP parameter numbers PNU in the sections
B.4.4 to B.4.10.
Device Data
FHPP
Class 100 (0x64)
CLS
ATTR INST
PNU
SI
Manufacturer Hardware Version BCD
100
1
1
100
0
Manufacturer Firmware Version BCD
100
2
1
101
0
Version FHPP
100
3
1
102
0
Version FCT PlugIn
PlugIn Min. BCD
100
4
1
104
1
PlugIn Opt. BCD
100
5
1
104
2
Controller Type
100
6
1
115
0
Controller Serial Number
100
8
1
114
1 ... 12
Manufacturer Device Name
100
9
1
120
1 ... 30
User Device Name
100
10
1
121
1 ... 25
Drive Manufacturer
100
11
1
122
1 ... 30
HTTP Drive Catalog Address
100
12
1
123
1 ... 30
Festo Order Number
100
13
1
124
1 ... 30
Device Control
100
14
1
125
0