B. Parametrizing via field bus

B−113

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Limit Switch Polarity

PNU

1300

ć

ć

int16

rw

Description

Limit switch type:

0 = no limit switch
1 = N/C contact
2 = N/O contact

CI

6510h

11h

int16

rw

DeviceNet

C: 103

Aā: 74

I: 1

int16

rw

Limit Switch Selector

PNU

1301

ć

ć

int16

rw

Description

Input for limit switch.
0 none
1 IN0 = limit switch negative

IN1 = limit switch positive

2 IN0 = limit switch positive

IN1 = limit switch negative

3 IN0 = limit switch negative

IN2 = limit switch positive

4 IN0 = limit switch positive

IN2 = limit switch negative

5 IN1 = limit switch negative

IN2 = limit switch positive

6 IN1 = limit switch positive

IN2 = limit switch negative

CI

6510h

12h

int16

rw

DeviceNet

C: 103

Aā: 75

I: 1

int16

rw

Homing Switch Selector

PNU

1302

ć

ć

int16

rw

Description

Input for reference switch:

0 = none

1 = IN0

2 = IN1

3 = IN2

CI

6510h

13h

int16

rw

DeviceNet

C: 103

Aā: 76

I: 1

int16

rw