Festo Контроллеры двигателя SFC-LAC User Manual
Page 333
B. Parametrizing via field bus
B−113
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Limit Switch Polarity
PNU
1300
ć
ć
int16
rw
Description
Limit switch type:
0 = no limit switch
1 = N/C contact
2 = N/O contact
CI
6510h
11h
int16
rw
DeviceNet
C: 103
Aā: 74
I: 1
int16
rw
Limit Switch Selector
PNU
1301
ć
ć
int16
rw
Description
Input for limit switch.
0 none
1 IN0 = limit switch negative
IN1 = limit switch positive
2 IN0 = limit switch positive
IN1 = limit switch negative
3 IN0 = limit switch negative
IN2 = limit switch positive
4 IN0 = limit switch positive
IN2 = limit switch negative
5 IN1 = limit switch negative
IN2 = limit switch positive
6 IN1 = limit switch positive
IN2 = limit switch negative
CI
6510h
12h
int16
rw
DeviceNet
C: 103
Aā: 75
I: 1
int16
rw
Homing Switch Selector
PNU
1302
ć
ć
int16
rw
Description
Input for reference switch:
0 = none
1 = IN0
2 = IN1
3 = IN2
CI
6510h
13h
int16
rw
DeviceNet
C: 103
Aā: 76
I: 1
int16
rw