C.1.3 access via a terminal program, C.1.3, Access via a terminal program – Festo Контроллеры двигателя SFC-LAC User Manual

Page 341

Advertising
background image

C. CI interface

C−5

Festo GDCP−SFC−LACI−DN−EN en 0812NH

C.1.3

Access via a terminal program

For data transmission you will require a commercially−availĆ
able terminal program or the integrated CI terminal of the
SFC−LAC PlugIn in the Festo Configuration Tool.

1. Connect the SFC−LACI to your PC (see section 3.5).

2. Configure your PC’s COM interface:

Settings of the COM interface

Transmission speed (baud rate)

38400 Baud

Data format

Asynchronous character frame:
Ĉ 1 start bit
Ĉ 8 data bits
Ĉ No parity bit
Ĉ 1 stop bit

Tab. C/1:

Settings of the COM interface

3. You can use the following command to initialise data

transmission and determine the SFC−LACI’s response
readiness:

Command

Reply

1 <CR>

11 <CR>