3. Installation

3−7

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Connection

Pin

Designation

Function

Cable
colourĂ

1)

A1

Load voltage

+48 VDC load

Black, 1

A2

Load voltage

GND load

Black, 2

1

Logic voltage

+24 VDC logic

White

2

Logic voltage

GND logic

Brown

3

Hardware
enable

+24 VDC
hardware enable

Green

4

FE

FE

3)

ć

2)

5

Hardware
enable

GND hardware
enable

Yellow

ć

Plug housing

FE

3)

Earthing strap
with cable lug
M4

Earth
terminal
(housing)

FE

3)

ć

1)

Cable colours with supply cable type KPWR−MC−1−SUB−15HC−...

2)

With cable type KPWR−MC−1−SUB−15HC−... not connected.Ă

3)

Use only one connection; see section 3.3

Tab. 3/3:

Power" connection (voltage supply) on the SFC−LACI

Caution
Damage to the device

The power supply inputs on the SFC−LACI have no special
protection against overvoltage.

·

Make sure the permissible voltage tolerance is never
exceeded; see Tab. 3/4.

Advertising