B. parametrizing via field bus b−25 – Festo Контроллеры двигателя SFC-LAC User Manual

Page 245

Advertising
background image

B. Parametrizing via field bus

B−25

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Notes on representing the finite status machine

The transition T3 changes to state S4, which itself contains its
own sub−state machine, the states of which are marked with
SAx" and the transitions of that are marked with TAx". This
enables an equivalent circuit diagram to be used, in which the
internal states SAx are omitted:

Switched off

S1

Controller

switched on

S4

Drive enabled

S2 Drive locked

S5 Reaction to

fault

S6 Malfunction

From all statuses

Operation

enabled

T6

T2

T5

T3

T4

T1

T7*

T8

T10

T9

S5

T11

S4

Fig. B/2: Finite state machine equivalent circuit diagram

Transitions T4, T6 and T7* are executed from every sub−state
SAx and automatically have a higher priority than any
transition TAx. Such a structure is a simplification. It is not
therefore necessary to define out of each SAx state a
separate transition as per S3 for the reaction to STOP
(S3:Ădrive held stationary).

Reaction to faults

T7 (Fault recognised") has the highest priority and receives
the asterisk āā*āā".

T7 is then derived from S5 and S6 when an error of higher
priority occurs. As a result, a slight error can displace a
serious error.