Page 319
B. Parametrizing via field bus
B−99
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Max. Current
PNU
1034
ć
uint16
rw
Description
Maximum motor current in per mill of rated current (see PNU 1035).
Note:
The current limitation also limits the max. possible speed (or force).
Higher setpoint speeds may not therefore be reached, or the drive stops.
During homing: At greatly reduced values combined with high travelling
resistance, there is a danger that the drive will come to a standstill and the
SFC−LACI will wrongly recognize a stop.
CI
6073h
00h
uint16
rw
DeviceNet
C: 107
Aā: 64
I: 1
uint16
rw
Motor Rated Current
PNU
1035
ć
uint32
rw
Description
Nominal current of the motor in [mA]. The value is fixed
CI
6075h
00h
uint32
rw
DeviceNet
C: 107
Aā: 65
I: 1
uint32
rw
Motor Rated Torque/Force
PNU
1036
ć
uint32
rw
Description
Nominal force of the linear motor in [mN]. The value is fixed
CI
6076h
00h
uint32
rw
DeviceNet
C: 107
Aā: 66
I: 1
uint32