Record Table Element CI

CI

20E0h

01h ... 0Bh

Record

Various

rw

Description

Editing the entries in the positioning record table:
1. Selection of line with object 2032h (record pointer).
2. Selection of column under subindex 20E0: 01 ... 0Bh

20E0/01

20E0/02
V

20E0/03

20E0/04

20E0/05

20E0/...

Record
number

RCW

Target
position

Velocity

AccelerĆ
ation

Jerk

...

02

2032h

}

03

<1>

<...>

...

The values are only saved in the position record table with this command;
noĂmovement is made.

Record Control

Word (RCW)

20E0h

01h

uint16

Word (RCW)

Record control word (RCW). Corresponds to 20EAh and 20EBh
Bit 0:

= 0 absolute position specified;
= 1 relative position specified

Bit 1 ... 2:

= 00 Standard path generator;
= 11 Energy optimised path generator

Bit 3 ... 7:

Not used (= 0)

Bit 8:

= 0 No further record switching;
=1 further record switching

Bit 9 ... 14: Not used (= 0)
Bit 15:

= 0 Record chaining is not locked out;
= 1 Record chaining is locked out

Note:
The energy optimised path generator enables higher dynamics with less heat;
the parameterised positioning curve (a trapezoid) is not maintained exactly.
The parameterised maximum values for speed and acceleration may be slightly
exceeded.

Target Position 20E0h

02h

int32

Target position in [Increments] (corresponds to 607Ah and 20ECh)

Velocity

(speed)

20E0h

03h

int32

(speed)

Speed in [Increments/s] (corresponds to 6081h und 20EDh)

Acceleration 20E0h

04h

int32

Acceleration in [Increments/s

2

] (corresponds to 6083h and 20EEh)