Festo Контроллеры двигателя SFC-LAC User Manual

Page 322

Advertising
background image

B. Parametrizing via field bus

B−102

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Measurement System Resolution

PNU

1051

ć

uint32

r

Description

Measurement resolution: Number of increments between two index pulses
(fixed = 2048)

CI

6410h

12h

uint32

r

DeviceNet

C: 107

Aā: 90

I: 1

uint32

r

Measurement System Pitch

PNU

1052

ć

uint32

r

Description

Measurement graduation: Distance [

ìm] between two index pulses

CI

6410h

13h

uint32

r

DeviceNet

C: 107

Aā: 91

I: 1

uint32

r

Nominal Power

PNU

1053

ć

uint32

r

Description

Nominal power of the linear motor in [W]

CI

6410h

14h

uint32

r

DeviceNet

C: 107

Aā: 47

I: 1

uint32

r

Actual Power

PNU

1054

ć

uint32

r

Description

Actual power of the linear motor in [W]

CI

6410h

15h

uint32

r

DeviceNet

C: 103

Aā: 40

I: 1

uint32

r