5. Commissioning

5−37

Festo GDCP−SFC−LACI−DN−EN en 0812NH

CPOS

Control byte 2 (CPOS) controls the positioning sequences as
soon as the drive is enabled.

Control byte 2 (CPOS)

Bit

EN

Description

B0
HALT

Halt

= 1: HALT is not active
= 0: HALT is activated. The axis stops with a defined braking

ramp, the positioning job remains active (with B6 the
remaining path can be deleted)

B1
START

Start positioning job

With a

rising edge the current setpoint data will be

transferred and positioning started (record 0 = homing run)

B2
HOM

Start

Homing

With a

rising edge homing is started with the set

parameters.

B3
JOGP

Jog positive

The drive moves at the specified speed in the direction of
larger actual values, providing the bit is set. The movement
begins with the rising edge and ends with the falling edge.

B4
JOGN

Jog negative

The drive moves in the direction of smaller actual values,
seeĂbitĂ3.

B5
TEACH

Teach actual value

With a falling edge the current actual value of the position
will be transferred to the setpoint value register of the
currently addressed positioning task, see section 5.6.3.
The teach target is defined with PNU 520.

B6
CLEAR

Clear Remaining Position

In the HALT" status, a signal edge causes the positioning
task to be deleted and transfer is made to the Ready"
status.

B7
ć

ć

Reserved, must be set to 0