Parameters involved (record selection) – Festo Контроллеры двигателя SFC-LAC User Manual

Page 170

Advertising
background image

5. Commissioning

5−66

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Parameters involved (record selection)

The entries in the positioning table can be written via the
fieldĂbus (PNU 401 ... 417).

The composition of the positioning table as per FHPP is
described in section B.4.7. Record chaining is described in
section 5.6.5.

Overview of parameters involved (see section B.4.7)

Parameters involved

Description

FCT

PNU

CI

Mode (absolute/relative/energy optimised)

x

401

20E0/01h

Target position

x

404

20E0/02h

Velocity

x

406

20E0/03h

Acceleration

x

407

20E0/04h

Deceleration (=Braking)

x

408

20E0/0Ah

Acceleration jerk

x

409

20E0/05h

Mass of the working load (without tool mass)

x

410

20E0/06h

Damping time

x

415

20E6h
20E0/07h

Deceleration jerk

x

417

20E0/0Bh

Start (FHPP)

CPOS.B1 = positive edge: Start
Jogging and referencing have priority

Feedback (FHPP)

SPOS.B2 = 0: Motion complete
SPOS.B1 = positive edge: Acknowledge start
SPOS.B4 = 1: Drive moving

Requirements

Device control by PLC/field bus
Controller must be in status Operation enabled"
Record number must be valid

Tab. 5/16:

Parameters involved in Record Select mode

Advertising