Festo Контроллеры двигателя SFC-LAC User Manual

Page 360

Advertising
background image

C. CI interface

C−24

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Version FCT PlugIn Min

CI

2067h

00h

Var

V−String

r

Description

Minimum required FCT PlugIn version
Format = xx.yy" (xx = main version, yy = secondary version)

Version FCT PlugIn Opt

CI

2068h

00h

Var

V−String

r

Description

Optimum FCT PlugIn version
Format = xx.yy" (xx = main version, yy = secondary version)

Scaling

CI

20D0h

01h, 02h

Array

uint8

r

Description

Units of measurement and decimal places on the control panel.
See CI object 20FFh/PNU 126

Measuring Unit

01h

Definition of unit of measurement
The setting for the unit of measurement system only affects the display.
All parameters are converted to the given unit of measurement only during
writing or reading.
Note:
The SFC−LACI operates internally with metric units; the CI interface with
increments.
Value: fixed = 1: millimetres, e.g.Ămm, mm/s, mm/s

2

Scaling Size

(no of places after

02h

(no. of places after

dec. point) Number of places after the decimal point

Fixed = 2

Advertising