Force mode – Festo Контроллеры двигателя SFC-LAC User Manual

Page 301

Advertising
background image

B. Parametrizing via field bus

B−81

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Force mode

Stroke Limit

PNU

510

ć

uint32

rw

Description

Stroke limitation: Maximum permitted stroke with force control.

The distance of the actual position from the start position must not be more
than the amount specified in this parameter. In this way you can ensure that, if
force control is activated by mistake (e.g.Ămissing work item), the axis will not
perform an uncontrolled movement. This parameter is taken into account in all
control modes in which the position controller is not active in the status
Operation enabled." Monitoring can be deactivated when bit RCB1.B5 is set.

CI

60F6h

0

1h

uint32

rw

DeviceNet

C: 105

Aā: 10

I: 1

uint32

rw

Min Torque/Force

PNU

511

ć

uint16

r

Description

The lowest permitted torque of the motor in per mill of the rated value
(6076h/PNU 1036). Fixed = 300

CI

60F6h

0

5h

uint16

r

DeviceNet

C: 105

Aā: 11

I: 1

uint16

r

Max Torque/Force

PNU

512

ć

uint16

rw

Description

The highest permitted torque of the motor in per mill of the rated value
(6076h/PNU 1036).
Values: 0 ... 1000

CI

6072h

00h

uint16

rw

DeviceNet

C: 105

Aā: 12

I: 1

uint16

rw