4. Control panel (only type SFC−LACI−...−H2)

4−17

Festo GDCP−SFC−LACI−DN−EN en 0812NH

4.5.5

[Settings] [Jog mode]

You can use the arrow keys to move the drive continuously
(also possible without previous reference run). The software
end positions have no effect here.

4.5.6

[Settings] [BUS parameter]

Setting the field bus parameters

[BUS parameter] Param.

Description

[MAC ID]

0 ... 63
(0 ... 3Fh)

Field bus address of the SFC−LACI
Representation: 00 dec, 00 hex"...63 dec, 3F hex"

[Baudrate]

125 kBd
250 kBd
500 kBd

Field bus baud rate as per settings on master

[I/O Datalength]

8 / 16Ăbytes

Set I/O data length
Ĉ 8 bytes:

only FHPP standard (the SFC−LACI is controlled as per the
Festo Handling and Positioning Profile)

Ĉ 16 bytes:

FHPP standard and FPC (additional use of the FPC for
parameterising the SFC−LACI)

Tab. 4/6:

Menu [Settings] [BUS parameter]

The settings in this menu will be saved directly in EEPROM
where they are safe from poweer failures after confirmation
with OK <Enter>.

Note
The set field bus parameters first become effctive after
Power off/on" or after a software reset (object 20F1/03h).