5 [settings] [jog mode, 6 [settings] [bus parameter, Settings] [jog mode – Festo Контроллеры двигателя SFC-LAC User Manual
Page 101: Settings] [bus parameter
4. Control panel (only type SFC−LACI−...−H2)
4−17
Festo GDCP−SFC−LACI−DN−EN en 0812NH
4.5.5
[Settings] [Jog mode]
You can use the arrow keys to move the drive continuously
(also possible without previous reference run). The software
end positions have no effect here.
4.5.6
[Settings] [BUS parameter]
Setting the field bus parameters
[BUS parameter] Param.
Description
[MAC ID]
0 ... 63
(0 ... 3Fh)
Field bus address of the SFC−LACI
Representation: 00 dec, 00 hex"...63 dec, 3F hex"
[Baudrate]
125 kBd
250 kBd
500 kBd
Field bus baud rate as per settings on master
[I/O Datalength]
8 / 16Ăbytes
Set I/O data length
Ĉ 8 bytes:
only FHPP standard (the SFC−LACI is controlled as per the
Festo Handling and Positioning Profile)
Ĉ 16 bytes:
FHPP standard and FPC (additional use of the FPC for
parameterising the SFC−LACI)
Tab. 4/6:
Menu [Settings] [BUS parameter]
The settings in this menu will be saved directly in EEPROM
where they are safe from poweer failures after confirmation
with OK <Enter>.
Note
The set field bus parameters first become effctive after
Power off/on" or after a software reset (object 20F1/03h).