Festo Контроллеры двигателя SFC-LAC User Manual

Page 334

Advertising
background image

B. Parametrizing via field bus

B−114

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Homing Switch Polarity

PNU

1303

ć

ć

int16

rw

Description

Reference switch type: 0 = N/C contact

1 = N/O contact

CI

6510h

14h

int16

rw

DeviceNet

C: 103

Aā: 77

I: 1

int16

rw

Limit Switch Deceleration

PNU

1304

ć

ć

int32

rw

Description

Limit switch deceleration: Braking in [m/s

2

] with limit switch signal

CI

6510h

15h

int32

rw

DeviceNet

C: 103

Aā: 78

I: 1

int32

rw

Sample Input

PNU

1305

ć

ć

uint32

rw

Description

Input for on−the−fly measurement (position sampling)
Value = 1: Sampling at IN1
Value = 2: Sampling at IN2. See section 5.6.12

CI

6510h

16h

uint32

rw

DeviceNet

C: 103

Aā: 79

I: 1

uint32

rw

Sample Switch Polarity

PNU

1306

ć

ć

uint8

rw

Description

Type of proximity switch used for position sampling.
0 = N/C contact
1 = N/O contact

CI

6510h

1Ch

uint8

rw

DeviceNet

C: 103

Aā: 84

I: 1

uint8

rw

Advertising