B. Parametrizing via field bus

B−30

Festo GDCP−SFC−LACI−DN−EN en 0812NH

B.4

Reference FHPP Parameters

B.4.1

FHPP parameter groups

Group

PNU

Description

Device data

100 ... 199

Device identification and device−specific settings, version
numbers, identifier words, etc.

Diagnosis memory

200 ... 299

Memory for diagnostic events: Fault numbers, fault time,
incoming/outgoing event

Process data

300 ... 399

Current setpoint and actual values, local I/Os, status data etc.

Position record
table (= record list)

400 ... 499

A record contains all the setpoint value parameters required
for a positioning procedure

Project data

500 ... 599

Basic project settings. Maximum speed and acceleration,
project zero point offset, etc.
} These parameters form the basis of the position set table

Factor group

600 ... 699

Reserved

Axis data
Electric drives 1

1000 ... 1099

All axis−specific parameters for electric drives. Gear factor,
feed constant, reference parameter, etc.

Axis data
Electric drives 2

1200 ...

Enhancements

Tab. B/9:

Parameter groups (FHPP)