Festo Контроллеры двигателя SFC-LAC User Manual
Page 323
B. Parametrizing via field bus
B−103
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Offset Reference Point
PNU
1055
ć
int32
rw
Description
Distance in increments from the reference point to the retracted end position.
Must be stated when homing to a stop. See Tab. 1/3.
CI
6410h
16h
int32
rw
DeviceNet
C: 107
Aā: 92
I: 1
int32
rw
Commutation Status
PNU
1056
ć
uint8
r
Description
State of the commutation point search
0x00:
No commutation (default)
0x01:
Commutation point search active
0x10:
Commutation point successfully found
0xFE:
Error in commutation (POSITION PLAUSIBILITY ERROR)
0xFF:
Error in commutation (COMMUTATION POINT ERROR)
CI
2050h
00h
uint8
r
DeviceNet
C: 107
Aā: 74
I: 1
uint8
r
Record Power Consumption
PNU
1057
ć
uint32
r
Description
Power consumption in [W] during last positioning record
CI
6410h
17h
uint32
r
DeviceNet
C: 107
Aā: 93
I: 1
uint32
r