2 diagnostic memory, Diagnostic memory, And 6 – Festo Контроллеры двигателя SFC-LAC User Manual

Page 211

Advertising
background image

6. Diagnosis and fault display

6−15

Festo GDCP−SFC−LACI−DN−EN en 0812NH

6.4.2

Diagnostic memory

The diagnostic memory contains the last 16 diagnostic
messages. It is backed up if possible in the event of power
failure. If the memory is full, the oldest element will be
overwritten (ring buffer).

Structure of the diagnostic memory

Parameters

1)

PNU 200 (20C8

h

)

PNU 201 (20C9

h

)

PNU 202 (20CA

h

)

PNU 203 (20CB

h

)

Format

uint8

uint16

uint32

uint32

Meaning

Diagnostic event

Fault number

Time stamp

Cycle number

Subindex 1

Current diagnostic message

Subindex 2

Previous diagnostic message

...

...

Subindex 16

Oldest diagnostic message

1)

See section B.4.5

Tab. 6/8:

Diagnostic memory: structure

Configuration of diagnostic memory with PNU 204/(20CCh)

SI

Description

SpecifiĆ
cation

Min.

Max.

1

= 1: Record incoming and outgoing

*)

faults

= 2: Record only incoming faults

*)

Outgoing fault = Acknowledge the fault

1

1

2

2

= 1: Resolution time stamp 10 ms
= 2: Resolution time stamp 1 ms

1

1

2

3

Deleting the diagnostic memory
Ĉ Writing with value = 1 deletes the diagnostic memory.
Ĉ Read will always reply with value = 1.

0

0

1

4

Read the number of entries in the diagnostic memory

0

0

16

Tab. 6/9:

Diagnostic memory: configuration

Advertising