Festo GDCP−SFC−LACI−DN−EN en 0812NH

Position Control Parameter

PNU

1024

18

d

... 21

d

int32

rw

Description

Caution: Risk of injury to people and damage to property!
The factory settings for the controller parameters should only be
modified in exceptional cases. Unfavourable settings can lead to
uncontrollable behaviour of the entire system.

·

Only change the controller parameters with the aid of FCT.

·

Follow the instructions in FCT for the controller parameters.

Position Controller

Closed Loop

1024

18

d

(CI: 12h)

Aā: 34

Closed Loop

Internal Frequency Position controller: circuit frequency. Value range: 1 ... 1000

Position Controller

Damping

1024

19

d

(CI: 13h)

Aā: 35

Damping

Position controller: damping. Value range: 100 ... 5000

Current Controller

Gain

1024

20

d

(CI: 14h)

Aā: 36

Gain

Current controller: gain. Value range: 100 ... 10000

Current Controller

Integrating Time

1024

21

d

(CI: 15h)

Aā: 37

Integrating Time

Constant Current controller: I−share. Value range: 1 ... 15000

CI

60FBh

12h ... 15h

int32

rw

DeviceNet

C: 107

Aā: 34 ... 37

I: 1

int32

rw

Motor Data

PNU

1025

1, 3

uint32

r

Description

Serial Number 1025

1

Aā: 44

Serial number of the motor

I

2

t Factor 1025

3

Aā: 45

I

2

t factor. See PNU 1027

CI

6410h

01h, 03h

uint32

r

DeviceNet

C: 107

Aā: 44 ... 45

I: 1

uint32

r