6. Diagnosis and fault display

6−8

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Warnings

Warnings have no influence on the behaviour of the drive.
The cause of the warning should be eliminated in order that it
does not lead to a malfunction.

If a warning occurs, the error LED will flash and the SCON.B2
WARN output will be set (FHPP status bits, see section 5.5.2).

Warning

Cause

PNU 215

Fault no.

*)

INDEX PULSE
WARNING

During homing: The homing switch signal lies too
close to the index pulse. In some cases Ăthis can mean
that no reproducible reference position can be
determined.

·

See section 6.6

0x0001

84

WARNING
MOTOR COLD

Temperature of the linear motor <Ă−10 °C
Increase the ambient temperature as appropriate.

0x0002

108

WARNING
MOTOR HOT

Temperature of the linear motor 70 ... 75 °C
Check for possible overloading of the drive; check the
mechanical system, e.g. for sluggishness; reduce
ambient temperature.

0x0004

109

WARNING
SFC−LACI COLD

Temperature <āāĂ −10 °C

0x0008

74

WARNING
SFC−LACI HOT

Temperature 80 ... 85 °C

0x0010

75

STANDSTILL
WARNING

The axis has moved outside the standstill tolerance
window

0x0020

36

ILLEGAL
RECORD
WARNING

Impermissible record number

0x0040

3

*)

Fault number in the diagnostic memory, see section 6.4.2.