3. Installation

3−21

Festo GDCP−SFC−LACI−DN−EN en 0812NH

3.7.4

Connection with field bus plugs / adapters from Festo

With Festo field bus plugs type FBS−SUB−9−BU−2x5POL−B or
the field bus adapter FBA−2−M12−5POL you can connect the
SFC−LACI to the field bus in a user−friendly manner. You can
disconnect the plug from the SFC−LACI without breaking the
bus connection (T−Tap function).

Ö

2

3

1

4

5

6

1

Field bus

2

Voltage supply

3

Screening

4

T−adapter (T−Tap)

5

Branch line

6

Field bus plug with T−adapter function

Fig. 3/5:

Layout of the bus interface and example of connection