background image

B. Parametrizing via field bus

B−66

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Record pointer:
The active record for

positioning or teaching is selected via

PNU 400.

Record Number FHPP

PNU

400

1 ... 3

Array

uint8

r(w)

Description

Record Number 400

1

rw

Record pointer for positioning and teaching.
It is also valid when the drive is not in Record Select mode (e.g. during teaching).
For record selection this parameter is transferred in the cyclic I/O data.
Value range: 0 ... 34 (0x00 ... 0x22)
Values:
0 (0x00):

Homing (positioning record 0)

1 (0x01):

Positioning record 1

2 (0x02):

Positioning record 2

...:

Positioning record ...

31 (0x1F):

Positioning record 31

32 (0x20):

Jog mode

33 (0x21):

Direct mode

34 (0x22):

FCT positioning record

Active Record 400

2

r

The number of the active record; relevant for record chaining

Record Status Byte 400

3

r

Contains FHPP status byte 4 with information on record chaining
(see section 5.5.2)

CI

2033h

01h ... 03h

uint8

r(w)

Note: The object 2032h is provided for access via CI.

DeviceNet

C: 103

Aā: 32 ... 34

I: 1

uint8

r(w)