Direct mode: specification of a position or force – Festo Контроллеры двигателя SFC-LAC User Manual

Page 172

Advertising
background image

5. Commissioning

5−68

Festo GDCP−SFC−LACI−DN−EN en 0812NH

5.6.6

Direct mode: Specification of a position or force

In the status Operation enabled" a positioning task is
formulated directly in the I/O data which are transmitted via
the field bus. The setpoint values for position or force/torque
are managed in the PLC.

The function is used in the following situations:

ć

moving to any position.

ć

the target positions are unknown during planning or
change frequently (several different work item positions).

A positioning profile using chained records can be externally
implemented by the master.

Procedure for specifying a position

1. The user sets the desired setpoint values into the PLC

output data:
CDIR.B1/2: Positioning mode control mode, possibly

energy optimised,

CDIR.B0:

Setpoint position absolute/relative

FHPP control byte 4:

Velocity setpoint value,

FHPP control bytes 5 ... 8: Position setpoint value

2. With a rising edge at START (CPOS.B1) the controller

accepts the setpoint position and starts the positioning
job.

3. After the start, you must wait for MC (SPOS.B2) before a

new start can be made.

4. When the setpoint position is reached, MC is set.

Advertising