B. Parametrizing via field bus

B−105

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Lower Coil Temp Threshold

PNU

1062

ć

uint16

rw

Description

Lower temperature threshold of the coils (= motor): 70 °C
A warning is triggered when this temperature is reached.

CI

6410h

33h

uint16

rw

DeviceNet

C: 107

Aā: 82

I: 1

uint16

rw

Upper Coil Temp Threshold

PNU

1063

ć

uint16

rw

Description

Upper temperature threshold of the coils (= motor): 75 °C
An error message is triggered when this temperature is reached.
Restart only after the temperature has dropped below the lower threshold
(seeĂPNU 1062).

CI

6410h

34h

uint16

rw

DeviceNet

C: 107

Aā: 83

I: 1

uint16

rw

Output Stage Actual Temperature

PNU

1066

ć

int16

r

Description

Temperature of the SFC−LACI output stage. Range: −20 ... +120 °C

CI

6

510h

31h

int16

r

DeviceNet

C: 107

Aā: 86

I: 1

int16

r

Output Stage Max Temperature

PNU

1067

ć

int16

r

Description

Highest temperature measured to date for the SFC−LACI, in °C.
Stored in EEPROM

CI

6510h

32h

int16

r

DeviceNet

C: 107

Aā: 87

I: 1

int16

r