B. Parametrizing via field bus
B−70
Festo GDCP−SFC−LACI−DN−EN en 0812NH
Record Delay
PNU
405
1 ... 32
d
int32
rw
Description
Waiting time for record chaining (= set chaining): The time between
Motion Complete" of a chained positioning record and the start of the
next positioning record.
Value range: 1 ... 60000 ms
Record 0
(positioning record 0)
405
1
(positioning record 0)
Do not use (Homing)
Record 1
(positioning record 1)
405
2
(positioning record 1)
Delay after positioning record 1
Record ...
(positioning record
)
405
...
(positioning record ...)
Delay after positioning record 2 ... 30
Record 31
(positioning record 31)
405
32
(positioning record 31)
Delay after positioning record 31
CI
20E4h
01h ... 20h
int32
rw
Note: The object 20E0h/08h is provided for access via CI.
DeviceNet
C: 104
Aā: 5
I: 1 ... 32
int32
rw