5. Commissioning

5−12

Festo GDCP−SFC−LACI−DN−EN en 0812NH

When homing to a fixed stop

1. Measure the distance between your reference point and

the retracted end position (Offset

Ref

} Tab. 1/3).

2. Enter the value (±1Ămm) in FCT or via the object

6410/16hĂ/ PNU 1055.

Note
Controller inaccuracies

If you do not enter the offset of the reference point, control
inaccuracies (e.g.Ăovershooting) can occur with small
(100Ămm) and large nominal strokes (400Ămm).

When homing to the drive’s integrated reference switch,
the reference point position is known (6 mm) and must not
be entered. This reference switch must not be moved.

Caution
Damage to components when the permissible impact
pulse is exceeded.

·

Operate the drive only with the permitted load
(see operating instructions for the drive).

·

If necessary, limit the maximum current (motor force)
during the homing run using:

Ĉ FCT ć or

Ĉ object 6073h / PNU 1034 Max. Current".