Parameter homing run – Festo Контроллеры двигателя SFC-LAC User Manual

Page 312

Advertising
background image

B. Parametrizing via field bus

B−92

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Parameter homing run

Offset Axis Zero Point

PNU

1010

ć

int32

rw

Description

Offset of the axis zero point AZ to the reference point REF in [Increments]
(=Ădistance from the reference point). Factory settings: see section 5.2.5.
The drive is no longer referenced after the axis zero point has been modified.

CI

607Ch

00h

int32

rw

DeviceNet

C: 107

Aā: 20

I: 1

int32

rw

Homing Method

PNU

1011

ć

uint8

rw

Description

Homing method
Values

Function

1 (0x01):

Search for limit switch in negative direction with index search

2 (0x02):

Search for limit switch in positive direction with index search

7 (0x07):

Search for reference switch in positive direction with index search

11 (0x0B):

Search for reference switch in negative direction with index search

−18 (0xEE): Search for stop in positive direction
−17 (0xEF): Search for stop in negative direction
The drive is no longer referenced after the homing method has been modified.

CI

6098h

00h

uint8

rw

DeviceNet

C: 107

Aā: 21

I: 1

uint8

rw