1 specifications of the outputs, Specifications of the outputs – Festo Контроллеры двигателя SFC-LAC User Manual
Page 82
3. Installation
3−28
Festo GDCP−SFC−LACI−DN−EN en 0812NH
3.9.1
Specifications of the outputs
The local digital outputs are supplied by the 24−V logic
voltage (no electrical isolation). They are ESD−protected and
short circuit proof, but do not have reverse polarity
protection against infeed.
Caution
If 24 V DC voltage is applied and the output pins are used
incorrectly, the device may be seriously damaged.
Therefore:
·
Do not apply voltage to the outputs.
·
Note the current limitation for the outputs
(max. 1 A permissible per output).
Special features of output 1 (Out1)
ć
Standard PLC output (active high−side switching)
Special features of output 2 (Out2)
ć
Differential output (can be pulse−width modulated)
ć
High− und low−side switching (active full bridge)
ć
It is not used for controlling a PLC, but rather for
controlling a load, e.g. to control a pulsed motor brake,
aĂvalve or a fan.
The possible uses dependent on the selected pins are
described in section 5.6.10.