2 led status displays, Led status displays, N 6.2 – Festo Контроллеры двигателя SFC-LAC User Manual
Page 201: 2 led status displays voltage supply, Malfunction indicator
Advertising
6. Diagnosis and fault display
6−5
Festo GDCP−SFC−LACI−DN−EN en 0812NH
6.2
LED status displays
Voltage supply
POWER
Status
Logic and load voltages applied
Green
Logic voltage is present
Load voltage is
not present or missing hardware enable
Flashing
There is no voltage
Off
Tab. 6/3:
LED Power"
Malfunction indicator
ERROR
Status
Error
The SFC−LACI is not ready for operation
Red
Warning
Check cause and rectify if necessary; see section 6.3
Flashing
No internal malfunction indicated
Off
Tab. 6/4:
LED Error"