Homing methods to the stop

Exact homing by reference to a fixed stop can only be carried
out against externally fitted stops (without rubber buffer or
similar). Therefore you should preferably use the homing
methods to switch.

Homing methods to the stop

Ĉ Negative fixed stop (retracted end position, near to motor)

REF

Offset

Ref

1

2

REF

AZ

+

Ĉ Positive fixed stop (extended end position, remote from motor)

1

2

AZ

ć

REF

Offset

Ref

3

REF

1 The drive (here: DFME−...−LAS) moves at search speed v_rp

to

the fixed stop (= reference point).

2 The drive moves at speed v_zp from the reference point to the

axis zero point AZ. The offset must be

š 0 !

3 Externally fitted fixed stop

Tab. 1/3:

Homing to the stop