5. Commissioning

5−5

Festo GDCP−SFC−LACI−DN−EN en 0812NH

5.1.1

Checking the drive

Note
During operation, the drive must not strike a stop without
shock absorption.

·

Use shock absorbers or buffers on all stops
(exception: homing to a fixed stop).

·

Before commissioning, make sure that drive and
controller are completely set up and wired and that the
working space is adequate for operation with an effective
load.

·

Observe the notes in the operating instructions for the
axis used.

5.1.2

Checking the power supply

Caution
Interruption of running tasks due to inadequate load
voltage supply (LOAD POWER DOWN")

·

Make sure that the load voltage supply tolerance can be
maintained at full load directly on the voltage terminal of
the SFC−LACI (see section 3.2).

Caution
Loss of reference position due to inadequate logic supply
voltage

·

Always carry out a homing run every time the logic
voltage supply is switched on, in order to anchor the
measuring reference system to the reference point
(REF).

The SFC−LACI does not carry out any positioning tasks if it
is not referenced.