6. Diagnosis and fault display

6−9

Festo GDCP−SFC−LACI−DN−EN en 0812NH

Error messages

The drive is stopped in the event of an error. The fault LED is
illuminated, the output SCON.B3 FAULT is set.

1. Rectify the cause of the error.

2. Acknowledge the error message:

ć

Using <Enter> on the control panel.

ć

Using the Acknowledge Error" button in the FCT.

ć

via the field bus with a rising edge of the RESET signal
CCON.B3 or with a falling edge of the ENABLE signal.

Caution
If the drive is not under position control after the removal
of ENABLE, this may cause injury to people and material
damage

Ĉ With vertical or sloping drive mountings, the moving

mass might slide down; see section 1.1.3.

Error

Possible cause and remedy

PNU

Fault no.

*)

PLEASE ENFORCE
HOMING RUN

When starting a positioning record
Possible causes:
Ĉ Valid homing run has not yet been carried out
Ĉ Due to a logic voltage failure the reference

position has been lost

·

Carry out a homing run

PNU 205
0x0200

1

TARGET POSITION
OUT OF LIMIT

The specified target position is outside the
permitted positioning range

·

Check software end positions, target position
and reference (absolute or relative)

PNU 205
0x0800

2

INTERPOLATION
CYCLE TIME

For FHPP Continuous Mode: missing position
specification(s) or missing toggle bit

PNU

208

0x0001

7

LIMIT SWITCH
ACTIVATED

A limit switch has been actuated

·

Check the positioning dynamics (overswing?),
e.g.Ăusing trace diagrams in the FCT

·

Check switches and cables

PNU

208

0x004

8

*)

Fault number in the diagnostic memory, see section 6.4.2.